S5300/S7300 Stack Configuration Cases
Overview
Virtualization technology enables centralized management and port expansion by connecting switches with virtualization functions using virtualization ports and cables to form a virtual device. It offers advantages such as expanding port density, simplifying user management, and extending link capacity. Users can manage a group of switches as a logical object through a single IP, reducing IP address usage and facilitating management. To enable the virtualization function, users need to restart the device after configuring it through virtualization management.
Two Devices Stack Configuration Case
1.Network topology
2. Configuration is as follows
DUT1 configuration:
DUT1>enable
DUT1#config
DUT1_config#bvss
DUT1_config_bvss#bvss enable
DUT1_config_bvss#bvss domain-id 1
DUT1_config_bvss#bvss member-id 1
DUT1_config_bvs#bvss priority 10
DUT1_config_bvss#bvss mode normal
DUT1_config bvss#bvss interface 1 type cGigaEthernet port 1 group 1
DUT1_config bvss#bvss interface 2 type cGigaEthernet port 2 group 1
DUT1_config_bvss#quit
DUT1#write bvss-config
DUT1#reboot
DUT2 configuration:
DUT2>enable
DUT2#config
DUT2_config#bvss
DUT2_config_bvss#bvss enable
DUT2_config_bvss#bvss domain-id 1
DUT1_config_bvss#bvss member-id 2
DUT2_config_bvs#bvss priority 20
DUT1_config_bvss#bvss mode normal
DUT2_config bvss#bvss interface 1 type cGigaEthernet port 1 group 2
DUT2_config bvss#bvss interface 2 type cGigaEthernet port 2 group 2
DUT2_config_bvss#quit
DUT2#write bvss-config
DUT2#reboot
3. Use the following commands to check the virtualization configuration information:
Switch#enable
Switch#show bvss current-config
Switch#show bvss management
Three Devices Stack Configuration Case
1.Network topology
2. Configuration is as follows
DUT1 configuration:
DUT1>enable
DUT1#config
DUT1_config#bvss
DUT1_config_bvss#bvss enable
DUT1_config_bvss#bvss domain-id 1
DUT1_config_bvss#bvss member-id 1
DUT1_config_bvs#bvss priority 10
DUT1_config_bvss#bvss mode enhanced
DUT1_config bvss#bvss interface 1 type cGigaEthernet port 1 group 1
DUT1_config bvss#bvss interface 2 type cGigaEthernet port 2 group 2
DUT1_config_bvss#quit
DUT1#write bvss-config
DUT1#reboot
DUT2 configuration:
DUT2>enable
DUT2#config
DUT2_config#bvss
DUT2_config_bvss#bvss enable
DUT2_config_bvss#bvss domain-id 1
DUT2_config_bvss#bvss member-id 2
DUT2_config_bvs#bvss priority 20
DUT2_config_bvss#bvss mode enhanced
DUT2_config bvss#bvss interface 1 type cGigaEthernet port 1 group 2
DUT2_config bvss#bvss interface 2 type cGigaEthernet port 2 group 1
DUT2_config_bvss#quit
DUT2#write bvss-config
DUT2#reboot
DUT3 configuration:
DUT3>enable
DUT3#config
DUT3_config#bvss
DUT3_config_bvss#bvss enable
DUT3_config_bvss#bvss domain-id 1
DUT3_config_bvss#bvss member-id 3
DUT3_config_bvs#bvss priority 30
DUT3_config_bvss#bvss mode enhanced
DUT3_config bvss#bvss interface 1 type cGigaEthernet port 1 group 1
DUT3_config bvss#bvss interface 2 type cGigaEthernet port 2 group 2
DUT3_config_bvss#quit
DUT3#write bvss-config
DUT3#reboot
3. Use the following commands to check the virtualization configuration information:
Switch#enable
Switch#show bvss current-config
Switch#show bvss management
Note:
To enable stacking, it is necessary to use a 10G SFP+ port. Once the switch has been successfully restarted after stacking, the service port is set to shutdown by default. To enable individual ports, the no shutdown command can be used, or multiple ports can be configured simultaneously by using batch configuration. For instance, to configure Ethernet ports 1, 2, 3, and 4 on the master switch interface, enter the following command in the configuration mode.